Skip to main content

Air ions and respiratory function outcomes: a comprehensive review

Abstract

Background

From a mechanistic or physical perspective there is no basis to suspect that electric charges on clusters of air molecules (air ions) would have beneficial or deleterious effects on respiratory function. Yet, there is a large lay and scientific literature spanning 80 years that asserts exposure to air ions affects the respiratory system and has other biological effects.

Aims

This review evaluates the scientific evidence in published human experimental studies regarding the effects of exposure to air ions on respiratory performance and symptoms.

Methods

We identified 23 studies (published 1933–1993) that met our inclusion criteria. Relevant data pertaining to study population characteristics, study design, experimental methods, statistical techniques, and study results were assessed. Where relevant, random effects meta-analysis models were utilized to quantify similar exposure and outcome groupings.

Results

The included studies examined the therapeutic benefits of exposure to negative air ions on respiratory outcomes, such as ventilatory function and asthmatic symptoms. Study specific sample sizes ranged between 7 and 23, and studies varied considerably by subject characteristics (e.g., infants with asthma, adults with emphysema), experimental method, outcomes measured (e.g., subjective symptoms, sensitivity, clinical pulmonary function), analytical design, and statistical reporting.

Conclusions

Despite numerous experimental and analytical differences across studies, the literature does not clearly support a beneficial role in exposure to negative air ions and respiratory function or asthmatic symptom alleviation. Further, collectively, the human experimental studies do not indicate a significant detrimental effect of exposure to positive air ions on respiratory measures. Exposure to negative or positive air ions does not appear to play an appreciable role in respiratory function.

Peer Review reports

Introduction

Over the past 80 years, extensive literature has been published pertaining to the potential biological effects of air ions. One of the major topics within this literature concerns the effect on respiratory function and health consequences, both favorable and unfavorable, after exposure to ionized air [13]. Small air ions are electrically charged clusters consisting of atmospheric molecules or atoms that have lost or gained electrons to impart a net positive or negative charge [4]. Atmospheric space charge in the form of small air ions may be generated from natural sources, such as changes in atmospheric and weather conditions, including rain, wind, and snow, as well as natural radioactivity in geological formations, cosmic radiation, waterfalls, and combustion processes [4]. In addition, air ions are produced by air ionizer devices sold to clean indoor air of aerosols and particulate by electrostatic precipitation; they also are produced by corona activity on the surface of high voltage transmission conductors of alternating current (AC) and direct current (DC) transmission lines. Scientists and meteorologists have measured naturally occurring variations of the electrical charge in the air for more than 100 years [5].

Historically, a variety of physiological or health effects in relation to exposure to charged air ions have been suggested. In general, many researchers have indicated a beneficial or therapeutic effect on lung function, metabolic measures, and asthmatic symptoms after exposure to negative air ions [68]. In contrast, a few researchers have suggested that exposure to positively charged air ions may be associated with decreased pulmonary performance and may exacerbate asthmatic symptoms and other respiratory irritations [810]. Yet, the constellation of scientific evidence relating to either a beneficial or detrimental respiratory effect after exposure to charged air ions remains unclear and has not been systematically reviewed in the past 30 years. Further, there is skepticism that concentrations of air ions in the range of 100,000 ions/cm3 (i.e., 15/10-19), for example, would have biological effects at concentrations similar to one of the most toxic chemicals (e.g., botulism at 10-14) [11]. The published scientific studies on this topic span over 80 years, and vary by differences in research methodology, clinical and laboratory technology, statistical techniques and capabilities, study population dynamics, and changes in environmental factors.

Although published research on air ion exposure and respiratory outcomes span numerous decades, to our knowledge, there are no current reviews on this topic, aside from a recent Cochrane Collaboration evaluation of air ionizers and asthma, for which the researchers did not recommend the use of room air ionizers to reduce symptoms in patients with chronic asthma [1]. Thus, our objectives were to summarize and review the published human experimental studies of exposure to negatively and positively charged air ions and respiratory function and outcomes, such as clinical pulmonary measures and asthmatic symptoms. In addition, where appropriate, we quantified results for similar exposure and outcome groupings using meta-analytic methods and forest plot illustrations of the data.

Materials and methods

Literature search and study identification

A structured literature search was conducted to identify the cumulative literature on the effects of charged air ions on acute and chronic respiratory function measures in humans. An earlier comprehensive review of possible biological and health effects of DC transmission lines commissioned by the Minnesota Environmental Quality Board [12] was used to identify the relevant historical literature through 1982. To update and supplement these earlier studies, a literature search using the Medline (PubMed) bibliographic database was conducted to identify articles indexed between January 1, 1982 and July 1, 2011. The DIALOG search service also was used to retrieve studies from relevant life, environmental and behavioral sciences, engineering, and other technical databases, including El Servier Biobase and Embase. Both the PubMed and DIALOG searches employed the same search strings. For our PubMed search, we used Medical Subject Heading (MeSH) terms for air ionization, which yielded 518 articles. We then incorporated terms in the title and abstract which referenced the exposure (air ions, charged aerosols, corona ions, atmospheric ions, ionization, ionized air, heavy ions, or light ions) and outcomes (respiration, asthma, lung cancer, chronic obstructive pulmonary disease, allergy, or rhinitis) of interest. The literature review was supplemented by hand searching the reference lists of all retrieved studies on this topic. In addition, we checked the recent Cochrane Collaboration [1] review on ionizers and chronic asthma to identify English language studies1.

Articles were restricted to studies among human populations published in the English language. We included experimental studies of subjects exposed to negatively or positively charged (or both) small air ions in a controlled or uncontrolled environment. Specifically, studies were required to report exposure to air ions with respect to their relationship (typically involving data on individual or group mean comparisons) on respiratory function outcomes (e.g., forced expiratory volume [FEV]), metabolic or other physiologic measures (e.g., blood pressure), or asthmatic or subjective symptoms (e.g., wheezing). We excluded studies for which only fitness or physical performance was evaluated (unless data on respiratory function was documented), and we excluded articles based on human survey data as well as experimental studies of animals and isolated cells and tissues. No restrictions on the number of subjects evaluated in each study were imposed because of the wide variation in publication dates and experimental methodologies. Twenty-three studies, published between 1933 and 1993, on the acute and chronic respiratory effects of air ions were identified that met our inclusion criteria. Some non-respiratory outcomes of air ion exposure were described in these 23 studies and these outcomes were also reviewed to insure that any potentially relevant related effects were not overlooked.

Data extraction and statistical methods

Qualitative information (e.g., characteristics of study population, study design) and quantitative data (e.g., group mean data for peak expiratory flow rate [PEFR], changes in blood pressure) were extracted and tabulated from each experimental study that met the inclusion criteria for further review (Table 1). Studies varied by population characteristics, evaluation of ion polarity, and outcome measures. Thus, in an effort to harmonize research findings across studies, we created narrative summaries based on three general study outcome groupings: 1) pulmonary and ventilatory measures, 2) metabolic and other physiologic measures, and 3) subjective sensations and symptom relief. Moreover, because of the considerable variation in study parameters (e.g., negative vs. positive air ions), study populations (e.g., children with asthma, adult subjects), and outcomes measured (e.g., heart rate, subjective symptoms), we could not justify the combining of data across studies to be evaluated meta-analytically, aside from one exception. We meta-analyzed data from three studies on negative air ion exposure and PEFR [7, 13, 14].

Table 1 Descriptive characteristics of experimental studies on air ions and respiratory outcome measures

Random effects meta-analysis models were used to estimate weighted group mean differences in PEFR, 95% confidence intervals (CI), and corresponding p-values for heterogeneity. This type of model assumes that the study-specific effect sizes come from a random distribution of effect sizes according to a specific mean and variance [29]. The group means of the individual studies were weighted based on the inverse of the variance, which is related to the sizes of the study populations. Tests for heterogeneity were conducted and sensitivity analyses were generated to discern any potential sources of between-study variability. Analyses were conducted using Comprehensive Meta-Analysis (version 2.2.046; Biostat, Englewood, NJ).

Exposure considerations

Some important exposure considerations should be kept in mind in the assessment of the literature on the respiratory effects of air ions. First, except for one or two of the studies reviewed, air ions were generated by concentrating the electric field at the tips of metal needles to produce corona such that the air is ionized and charges are removed and added to gas molecules. Only rarely do studies of air ions consider that this process also generates small quantities of ozone and oxides of nitrogen to varying degrees. In the open air, the concentrations of these gasses to which people might be exposed are vanishingly small, being at the limits of detection even very close to the source [3032]. The operation of ionizers, however, if not properly designed, can lead to concentrations of these gases that are irritating to the respiratory tract in indoor environments. Indeed, the Food and Drug Administration became involved in the regulation of air ionizers because of concerns about excess ozone production and the lack of a scientific basis for medical device claims in the absence of “well controlled and valid scientific studies” [33, 34]. Second, the investigators in these studies also assume that the only exposures produced are to air ions. The lifetime of air ions is quite variable, but generally less than a few minutes in most environments [35]. Many air ions are neutralized by ambient air ions of opposite charge.2 Others are neutralized by contact with objects onto which the excess charge is transferred. After neutralization, air ions cease to exist but the charge transferred to aerosols may persist for many minutes or hours. While the essential character of an aerosol is not changed by the addition of electrical charges, it does enhance its susceptibility to forces from other charges. For example, one group of physicists have suggested that when even a single charge is acquired by an aerosol in the size range of 25–125 nm, the deposition of that aerosol on the respiratory tract is enhanced because of the attraction to charges of opposite polarity on its surface [36, 37]. Actual studies of the deposition of charged aerosols in human subjects, however, do not support this notion; only when nine or more charges are on such aerosols does deposition begin to increase [38]. Third, all of the experiments reviewed involved the use of air ion generators in indoor laboratory or home settings in which the air ionizers might increase the charge on aerosols above 10 Q per particle [39]; a result that would not occur in well-ventilated rooms or outdoors.

Summary of studies

The salient characteristics of individual studies including the objectives, study design, population, sample size, and primary outcomes of interest are summarized in Table 1. Table 2 summarizes the ion polarity and concentration of air ions to which subjects were exposed and the study results. The literature on air ion exposure in a controlled environment and respiratory function outcomes spans many decades, with studies published in the English language between 1933 and 1993. Thus, expectedly, the studies vary considerably in terms of study populations being evaluated, experimental design, and outcomes measured, among other factors. Some studies were randomized double-blind experiments, some studies were single blinded or did not incorporate randomization and investigator blinding, and some studies used a cross-over design with variations in experimental methods. The therapeutic effects of air ions, primarily negative polarity, were evaluated in most of the studies. As such, several studies examined the beneficial effect of negative air ions on study populations consisting of children and adults with pre-existing asthma and related respiratory conditions. A wide range of respiratory measures were studied, including respiratory rate, multiple measures of pulmonary function, and respiratory symptoms, after exposure to ionized air particles. Collectively, air ion exposure levels generally between 1,600 ions/cm3 and 1,500,000 ions/cm3 were measured in the majority of these studies, and the duration of exposure varied considerably across experiments from less than an hour in some studies to weekly intervals. The literature is summarized by general outcome categorizations in the following sub-sections.

Table 2 Experimental design and respiratory outcomes

Pulmonary and ventilatory measures

Herrington [3] exposed 11 healthy male volunteers aged 18 to 25 years (6 subjects in the morning group and 5 subjects in the afternoon group) to positive and negative air ions to examine the effects on subjects’ respiratory rate and found that no study participant exhibited significant changes attributed to air ion exposure. The author further confirmed this in a group analysis, whereby no meaningful difference overall in subjects’ respiratory rate was observed. Winsor and Beckett [9] conducted several experimental studies and the overall objectives were to determine if the human body acted as a collector of atmospheric ions and to examine the biologic effects of positive and negative air ion exposure. Only one of their experiments, however, evaluated the respiratory effects of air ion exposure (n = 5 adults). In this study, the maximum breathing capacity (MBC) dropped from 35 L/min to 25 L/min following positive air ion exposure. In contrast, no significant change was observed following negative air ion exposure. Lefcoe [27] evaluated the impact of positive and negative air ion exposure among 24 adults with mild obstructive lung disease (15 mild to moderate asthma patients, 5 mild bronchitis patients, and 4 patients with a history of hay fever) on forced vital capacity (FVC), FEV1, and maximum mid-expiratory flow rate (MMFR) measurements. No significant effects on respiratory function between exposure to positive, negative, and no ionization were reported. Blumstein et al. [2] conducted a double-blind randomized study to investigate the influence of positive and negative air ion treatment on allergic respiratory conditions in 26 adults (12 hay fever cases, 10 asthma cases, and 4 pulmonary emphysema cases) and found no significant changes in patients’ conditions when subjectively or objectively assessed by vital capacity, timed vital capacity (TVC1 and TVC3), MBC, the maximum expiratory flow rate, and the single breath test.

In a cross-over experiment conducted by Reilly and Stevenson [24], oxygen uptake (VO2) and minute ventilation (VE) were examined in eight healthy adult males (age range: 19–25 years) exposed to negative air ions. Measurements were taken both at rest and during two consecutive 20-minute sessions of physical activity. The authors observed a significant reduction in mean V02 levels and VE between non-ionized and ionized conditions in resting subjects. In contrast, no significant impact of air ions on V02 levels and VE were identified during physical activity. When the authors examined differences between conditions in the delta (exercise minus rest) values of these outcomes, a significant elevation in both V02 levels and VE was noted in the ionized compared to non-ionized conditions.

Motley and Yanda [28] conducted multiple experimental, non-randomized studies among different adult populations to examine the influence of negative and positive air ions on pulmonary function as determined by TVC, FEV, MBC, and mean peak flow rates. In one study of 46 adults with severe emphysema or fibrosis, or both, 13 patients were exposed to negative air ions for 1 hour and 33 patients were exposed to negative air ions for 3 hours, and no significant effect on lung volume measurements were observed. Similarly, the authors reported no significant effect of negative air ion exposure (7 to 12 hours daily for 2 weeks) on lung volume measurements in 19 patients with severe pulmonary emphysema; no significant differences between these 19 patients and 7 unexposed control subjects; and no significant alterations in blood gas exchange measurements (after exposure to negative and positive air ions) or chronic pulmonary disease in 44 and 35 cases, respectively.

Jones et al. [7] performed an experiment during a 16-week period to determine the efficacy of negative air ion treatment for bronchial asthma in seven patients (six males and one female) aged 10 to 54 years. Monthly measurements of lung function included FEV1, PEFR, forced mid-expiratory flow, FVC, and static lung volumes. The authors observed that four subjects experienced a significant increase in morning PEFR during the exposure period, but this effect was no longer present in two of these subjects during the subsequent non-air-ion exposure period. In a two-way group analysis, however, they reported that the patients as a whole showed no statistically significant differences between the placebo, treatment, and no treatment periods. Albrechtsen [21] examined pulmonary changes (FEV1, histamine threshold) after exposure to positive and negative air ions in 15 patients (8 males and 7 females) aged 16 to 48 years with bronchial asthma. All patients underwent extended allergy testing. In group 1, the researchers identified significant alterations in FEV1 between air ion and non-air-ion conditions and individual FEV1 levels were significantly greater during both negative and positive air ion exposure periods. Group 2, however, showed no significant change in histamine threshold following air ion exposure and no obvious difference was observed in FEV1 levels when subjects were exposed to either positive or negative air ions. The same authors Osterballe et al. [20] reported small, but statistically significant, improvements in lung function in nine of 15 patients with bronchial asthma, and no change in the histamine threshold of the airways in six patients after exposure to ions. Dantzler et al. [22] examined the effect of moderately extended positive and negative air ion exposure in nine adult patients (age range: 35–64 years) with bronchial asthma in a double-blind controlled study, and found that patients’ mean FEV1 did not significantly differ between exposures or from baseline.

Nogrady and Furnass [13] evaluated 19 adults (10 men and 9 women, mean age 36 years) in a double-blind crossover study to examine the impact of negative air ion exposure on bronchial asthma. In their 6-month study, the authors found no statistically significant differences in PEFR between active ionization and either placebo or no ionizer environments. Wagner et al. [25] conducted an experimental study to investigate the association between positive or negative air ions, random variations in meteorological factors (ambient temperature, barometric pressure, wind velocity, precipitation, and air pollution), and mean peak flow rates in six male and six female patients (age range: 41–69 years, mean age 54 years) with moderate to severe asthma. The authors found that mean peak flow rates did not differ significantly with alterations in air ion levels or other meteorological parameters linked to the occurrence of two weather fronts during the study.

Palti et al. [8] examined the effects of air ion exposure among 13 infants diagnosed with bronchial asthma and 6 comparison infants free of respiratory symptoms. The authors summarized that negative air ion exposure resulted in reduced respiratory spastic attacks while positive air ion exposure increased spastic attacks in normal infants, however, statistical significance testing was not performed to estimate the reliability of the reported effects. Lipin et al. [16] measured respiratory effects of positive air ions on 12 asthmatic children under physical exertion. Exercise tests were undertaken with and without exposure to positively charged inspired air using a randomized, double-blind design. The authors reported that the post-exercise fall in FEV1 was significantly greater (p = 0.04) during exposure to positive air ions compared with the control group, but no significant effects were observed for other comparisons (e.g., ventilation, oxygen consumption). In a previous analysis from this study group, Ben Dov et al. [6] evaluated the effect of negative ionization on bronchial reactivity among 11 asthmatic children. The experiment was double-blind and the children were challenged twice by exercise and by histamine inhalation. Exercise induced bronchial reactivity was reduced in all but one study subject, at concentrations of air ions in the mouthpiece approximately 100 to 1,000 times greater than typical background levels. No appreciable effects on resting lung function were observed, and the effect of ionized air on the sensitivity of inhaled histamine was equivocal. In another study of asthmatic boys ages 8 to 12 (n = 24), Kirkham et al. [15] analyzed the effects of negative air ionizers on lung mechanics. They found no significant differences in initial or post-study period lung function values between the groups. Warner et al. [14] evaluated the effect of ionizers on airborne concentrations of house dust mite allergen Der p I in a double-blind, crossover, placebo controlled trial. The study was carried out in the homes of 20 children with allergic asthma. Although there was a significant decrease in airborne Der p I concentrations, no significant changes were observed for PEFR, symptom scores, or treatment usage. The authors observed a trend in increased night time cough during the active ionizer period, but the association did not reach formal statistical significance.

Other physiologic measures

The studies included in this review were selected based on their analyses of respiratory effects; however, many of these studies also evaluated other measures as well. Thus, we evaluated other physiological measures in this group of respiratory studies to investigate other potential relationships with air ions. Yaglou et al. [10] performed an experimental study to evaluate metabolic changes (total metabolism, pulse rate, blood pressure, body temperature) during exposure to positive or negative air ions in 60 subjects (25 females and 35 males, age range: 10–68 years) under basal and routine dietary conditions. The study found comparable changes between positive and negative air ion exposure despite the concentration level used, and no noteworthy metabolic alterations attributable to ionization were identified. In a subsequent experimental study conducted by Yaglou [26], 25 healthy adults (17 males and 8 females, age range: 22–51 years) were exposed to positive or negative air ions for 1 to 2 hours in between pre- and post-test control periods. No significant differences in subjects’ metabolic rate, blood pressure, oral temperature, and red and white blood cell counts were found. The authors also conducted an experiment in six arthritic adult patients exposed to positive or negative air ions and observed no major changes in metabolism, heart rate, and blood pressure, except in anxious patients experiencing air ion treatment for the first time. In addition, they examined if negative air ion therapy was beneficial to the growth and development of five infants, and found that babies’ weight gain, heart rate, and body temperatures did not significantly change when exposed for 2 hours during a 2 week ionization period compared to non-ionization periods.

Summarized in the previous pulmonary section, Motley and Yanda [28], Dantzler et al. [22], Reilly and Stevenson [24], Herrington [3], and Lipin et al. [16] also examined metabolic parameters. Motley and Yanda [28] reported the pulse rate per minute between positive and negative air ion exposure in their blood gas exchange study (n = 44) and found that the average pulse rate was slightly lower when exposed to negative versus positive air ion therapy (77 vs. 81) but the authors did not conduct statistical significance testing. The Dantzler et al. [22] double-blind controlled study of nine adult patients showed no significant changes in the elimination of catecholamine metabolites or in pulse rate between positive and negative air ion exposures, but reported that mean blood pressure rose significantly between baseline and 2 hours of positive air ion exposure. In the cross-over study of eight healthy adult males performed by Reilly and Stevenson [24], negative air ion exposure resulted in statistically significant decreases in rectal temperature, heart rate, and metabolic rate at rest; however, no effects on metabolism and heart rate remained while subjects exercised. In the aforementioned experimental study conducted by Herrington [3], no study participant exhibited significant changes in basal or total metabolism, blood pressure, pulse rate, oral temperature, and total urine volume that were attributable to air ion exposure. Furthermore, no meaningful group differences in metabolic rate or blood pressure were observed. In a randomized, double-blind study of 12 asthmatic children, no significant differences were observed for heart rate or respiratory heat loss after exposure to positive air ions [16].

Subjective sensations and symptom relief

In the earlier Yaglou et al. [10] study discussed previously, the most prevalent sensation effects reported in the positive air ion experiments were dryness and irritation of the nose (13.5%), headache (13.5%), and an invigorating, stimulating sensation (10.8%), while others reported feeling no change (21.7%). On the other hand, the most prevalent sensations reported in the negative air ion experiments were relaxation (21.6%), a general cooling effect (12.9%), and sleepiness (12.9%), while a group reported feeling no change (27.6%). In their later experiment [40], Yaglou reported that negative air ion exposure did not impact subject’s perception of the quality of the air of 25 adult subjects, although positive air ion exposure appeared to increase upper respiratory tract irritation. The author noted that the majority of the experiments were conducted during the winter, when such sensations were more prevalent. In addition, reported joint symptoms did not improve when the arthritic patients under study were exposed to negative air ion therapy, while positive air ion exposure appeared to result in unfavorable symptomatic effects. The extremely small sample size greatly limits any possible inferences that could be made, however.

Zylberberg and Loveless [19] conducted a double-blind, controlled study on 16 asthmatic men and women (aged 15–53) during two 120-minute exposure periods to ionized air. No differences in the biologic effect of positive or negative air ions were observed, although dryness of the nose or throat was reported for both ion polarities. Kornblueh and Griffin [17] measured the efficacy of negative air ion treatment among an adult and child patient population (n = 27) who suffered from respiratory symptoms. The majority of patients were previously diagnosed with hay fever, while a few were diagnosed with asthma or variants of rhinitis. The authors indicated that the majority of subjects reported complete or partial relief for hay fever symptoms, but there was no appreciable effect for patients with asthma or rhinitis. In a subsequent publication by Kornblueh and colleagues [18], the effects of positive and negative air ions on hay fever symptoms were evaluated among 123 children and adults aged between 4 and 59. Exposure to negative air ions was associated with hay fever symptom relief among symptomatic subjects, but did not result in symptoms among asymptomatic subjects. Positive air ion exposure did not result in symptom alleviation, but was associated with the development of symptoms in asymptomatic subjects. Of note, the sample size of the positive air ion group was considerably smaller than the negative air ion group. Statistical testing was not performed. In the Dantzler et al. [22] study previously discussed, no statistically significant differences in reported somatic symptoms among eight study participants were observed between positive and negative air ion exposures. In a double-blind, crossover, placebo controlled trial of ionizers in the homes of asthmatic children, Warner reported no significant differences between groups for night/day wheeze, night time cough, or daytime activity [14].

“Sick building syndrome” has been described as discomfort within office buildings, and a deficiency of negative air ions has been hypothesized as contributing to symptoms. Thus, Finnegan et al. [23] conducted a survey in a “sick building” whose occupants had a high prevalence of symptoms to test for beneficial effects of negative air ion generators. Twenty-six subjects completed a questionnaire daily for 12 weeks to rate the environment and their physical comfort. There were no significant effects on environment or personal comfort factors. There were slightly more complaints of upper respiratory tract infections and nausea, but these may have been attributable to mild flu-like disorder.

Meta-analysis of PEFR

We were able to combine data from three studies (eight unique parameter estimates) in a meta-analysis that evaluated negative air ion exposure and PEFR [7, 13, 14]. The studies reported group mean values for PEFR in the morning and evening (Figure 1). The weighted difference in group means (i.e., PEFR after negative air ion exposure [post-test]; PEFR before negative air ion exposure [pre-test]) for the morning testing was 5.97 but this difference was not statistically significant (95% CI: -11.91 – 23.84). For the evening testing, the weighted difference in group mean values was attenuated and also not statistically significant (1.87, 95% CI: -15.72 – 19.46). When data for both morning and evening tests were combined, the weighted difference in group mean values was 3.88 (95% CI: -8.65 – 16.42) with virtually no statistical heterogeneity present (p-heterogeneity = 0.998). Blumstein et al. [2] reported group results for the maximum expiratory flow rate (L/min) in a bar chart, but did not report actual group data. Based on their bar chart, there does not appear to be an appreciable difference between group mean values comparing negative ionization with the control group. Overall, the meta-analysis findings were not supportive of a statistically significant effect of negative air ion exposure on PEFR measures.

Figure 1
figure 1

Difference in group means for PEFR (L/min) testing after exposure to negative air ions.

Discussion

Over several decades, the effects of artificially generated air ions on humans have been studied for both experimental and therapeutic purposes, and attempts have been made to investigate naturally occurring variations in air ion levels in relation to a variety of physiological conditions. To our knowledge, this is the first comprehensive review to summarize human studies of air ion exposure and respiratory outcomes other than those that were designed to test for potential therapeutic effects. Air ions are simply air molecules that have gained or lost electrical charges based on the displacement of an electron from a neutral gas molecule. In terms of physiological aspects, the interactions of air ions with the body are similar to interactions with other components of the air, such as oxygen and nitrogen, except that charged molecules and atmospheric aerosols carrying charges can be attracted to and deposited on the skin and respiratory tract by electrostatic forces. In regard to the respiratory tract, most of the air ions are retained in the nose and bronchi with few reaching the deep alveoli of the lung [12]; however, no mechanism has been established or confirmed to explain how air ions could exert any significant biological effect on respiratory or other systems [12]; NRPB, [41]. This is not surprising when one considers that even 100,000 ions represent an infinitesimal concentration in the air (100,000/1019 molecules in 1 cm3). Should air ions be deemed toxic, the threshold for effect would be lower than some of the most potent toxins (e.g., botulism) [11]. In fact, no scientific or regulatory agency has determined that small air ions pose a threat to the environment or health and no exposure guidelines have been proposed. The only guidelines for air ions have been published by the Ministry of Health of the Russian Federation for maintenance of optimal levels in indoor environments (i.e., maintaining levels of air ions at or above levels in clean outdoor air) because low levels of air ions in buildings have been alleged as symptomatic of poor indoor air quality [MHRF, [42]].

Synthesizing and examining the scientific evidence on a topic such as this is a challenging undertaking, which is complicated by the considerable variation in experimental methodology, study populations being evaluated, and differing outcome measures. A major strength across the majority of studies is the controlled experimental design, whereby the investigators or study participants, or both, may have been blinded to the exposure (i.e., ion polarity) parameters. In addition, the random allocation of subjects to exposed and control groups theoretically reduces the confounding influence of extraneous factors. Not all studies utilized blinding or randomization techniques, however, and approximately half of the studies examined sample sizes of less than 20, potentially resulting in diminished statistical power to observe a statistically significant effect in these studies. For example, the studies did not control for the reduction in particulate levels by air ionizers, and if a beneficial effect was reported, the result may have been due to the reduction of particulate levels, such as dust or allergens, in the room. Across studies, there is considerable variation in the way outcome information and data were analyzed, reported, and tested for significance. This heterogeneity may be due, in part, to the varying levels of scientific rigor and sophistication of statistical techniques available, given the expansive time frame and historical context in which the studies were published. For example, some studies simply reported data using graphical illustrations, some reported group averages, some reported clinical parameters for selected subjects, and some did not report data. In addition, the utilization of significance testing varied as did the reporting of variance data, such as standard deviations or confidence intervals. The lack of uniformity in terms of exposure factors (e.g., positive vs. negative air ions, group mean change in respiratory function vs. individual effect), outcome measure (e.g., PEFR, body temperature), and data reporting limits the feasibility to conduct a quantitative evaluation of the available literature, such as a meta-analysis.

Meta-analyses are becoming more and more prevalent in the peer-reviewed literature, and serve as a useful tool in weight-of-evidence evaluations and public policy and regulatory decision making. An important function of a meta-analysis is to estimate the collective strength of an association, examine the consistency of study findings, identify potential sources of between-study heterogeneity, and appraise the likelihood of publication bias. Although numerous studies on air ion exposure and respiratory outcomes have been published, as mentioned, considerable variation (e.g., study population differences, positive vs. negative polarity) across studies exists, precluding a formal comprehensive quantitative assessment. We were, however, able to combine data on negative air ion exposure and PEFR in a meta-analysis. This analysis indicated slight improvement in PEFR after exposure to negative air ions but the effect was not statistically significant. To more appropriately explore collective quantitative evaluations on air ion exposure and respiratory outcomes, any future studies should transparently document all analytical and statistical methods and data to facilitate a more uniform comparison of findings across studies. Indeed, in the aforementioned Cochrane Collaboration publication of effectiveness of positive and negative air ion generators among persons with asthma, the authors indicated that they could not reliably pool data together across studies [1].

Despite the limitations indicated above, the experimental studies reviewed here provide no persuasive evidence for an effect of charged air ions on respiratory effects, including pulmonary and ventilatory measures (Table 3), metabolic and physiologic parameters, and subjective symptom alleviation and sensations. This interpretation is largely based on fundamental factors that include the strength of effect and whether any effect is statistically significant and free from bias, confounding, or chance; evidence of dose–response relationships; and consistency of findings across studies. Collectively, in the majority of studies, the effects were relatively weak in magnitude (irrespective of the outcome evaluated), inconsistent as to the direction of the response, and not indicative of a dose–response trend. This observation is in concert with the aforementioned MEQB review, which stated that only minor symptoms (e.g., throat dryness) were related to experimental air ion exposures, with limited evidence of any dose–response relationships [12]. Further, in the MEQB review it was reported that short- and long-term exposures to positive and negative air ions do not affect persons with pre-existing allergies, asthma, or respiratory disease, or persons more sensitive to respiratory irritants. As mentioned, Blackhall et al. [1] also concluded that research has failed to demonstrate any benefit of air ionizers in the treatment of chronic asthma in children and adults.

Table 3 Reported overall study conclusions for air ions and pulmonary and ventilatory measures

Based on the constellation of literature spanning numerous decades and in light of variations in experimental study designs, study populations, outcome measurements, and analytical techniques, exposure to negative or positive air ions and any associated exposures to charged aerosols does not appear to play an appreciable role in respiratory function. Although some studies have reported a variety of pulmonary benefits after exposure to negatively charged air ions, and some studies have reported a few mildly unfavorable pulmonary responses after exposure to positively charged air ions, collectively, the literature does not provide any reliable evidence for effects of negative or positive air ions on pulmonary, respiratory, or metabolic measures.

Endnotes

1An examination of English abstracts of studies published in foreign languages did not suggest conclusions different from those based on studies published in English.

2About 1/3 of aerosols are positively charged, 1/3 negatively charged, and 1/3 without charge in a Boltzman equilibrium [NRPB, [41]].

References

  1. Blackhall K, Appleton S, Cates CJ: Ionisers for chronic asthma. Cochrane Db Syst Rev. 2003, CD002986

    Google Scholar 

  2. Blumstein GE, Spiegelman J, Kimbel P: Atmospheric ionization in allergic respiratory diseases: a double blind study. Arch Environ Health. 1964, 8: 818-819. 10.1080/00039896.1964.10663760.

    Article  Google Scholar 

  3. Herrington LP: The influence of ionized air upon normal subjects. J Clin Invest. 1935, 14: 70-80. 10.1172/JCI100660.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Bailey WH, Johnson GB, Bishop J, Hetrick T, Su S: Measurements of charged aerosols near ± kV DC transmission lines and in other environments. Ieee T Power Deliver. 2012, 27: 371-379.

    Article  Google Scholar 

  5. Chalmers JA: Atmospheric Electricity. 1967, New York: Pergamon Press

    Google Scholar 

  6. Ben-Dov I, Amirav I, Shochina M, Amitai I, Bar-Yishay E, Godfrey S: Effect of negative ionisation of inspired air on the response of asthmatic children to exercise and inhaled histamine. Thorax. 1983, 38: 584-588. 10.1136/thx.38.8.584.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. Jones DP, O'Connor SA, Collins JV, Watson BW: Effect of long-term ionized air treatment on patients with bronchial asthma. Thorax. 1976, 31: 428-432. 10.1136/thx.31.4.428.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Palti Y, De Nour E, Abrahamov A: The effect of atmospheric ions on the respiratory system of infants. Pediatrics. 1966, 38: 405-411.

    CAS  PubMed  Google Scholar 

  9. Winsor T, Beckett JC: Biologic effects of ionized air in man. Am J Phys Med. 1958, 37: 83-9.

    Article  CAS  PubMed  Google Scholar 

  10. Yaglou CP, Brandt AD, Benjamin LC: Observation of a group of subjects before, during, and after exposure to ionized air. J Ind Hygiene. 1933, 15: 341-353.

    Google Scholar 

  11. Toxicology Principles for the Industrial Hygienist. Edited by: Luttrell WE, Jederberg WW, Still KR. 2008, Fairfax, VA: American Industrial Hygiene Association

    Google Scholar 

  12. Bailey WH, Bissell M, Brambl RM, Dorn CR, Hoppel WA, Sheppard AR, Stebbings JH: A Health and Safety Evaluation of the ± 400 KV Powerline. 1982, St. Paul, MN: Minnesota Environmental Quality Board

    Google Scholar 

  13. Nogrady SG, Furnass SB: Ionisers in the management of bronchial asthma. Thorax. 1983, 38: 919-922. 10.1136/thx.38.12.919.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  14. Warner JA, Marchant JL, Warner JO: Double blind trial of ionisers in children with asthma sensitive to the house dust mite. Thorax. 1993, 48: 330-333. 10.1136/thx.48.4.330.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Kirkham AJT, Hawkins L, Guyatt AR, Lumley K, Horsfield K, Cumming G: The effect of air ionization on lung function in chronic asthmatics. Clin Sci. 1984, 67 (Suppl 9): 62-63.

    Google Scholar 

  16. Lipin I, Gur I, Amitai Y, Godfrey S: Effect of positive ionization of inspired air on the response of asthmatic children to exercise. Thorax. 1984, 39: 594-596. 10.1136/thx.39.8.594.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  17. Kornbleuh IH, Griffin JE: Artificial air ionization in physical medicine−a preliminary report. Amer J Physical Med. 1955, 34: 618-631.

    Google Scholar 

  18. Kornbleuh IH, Piersol GM, Speicher FP: Relief from pollinosis in negatively ionized rooms. Am J Phys Med. 1958, 37: 18-27.

    Google Scholar 

  19. Zylberberg B, Loveless MH: Preliminary experiments with ionized air in asthma. J Allergy. 1960, 31: 370-374. 10.1016/0021-8707(60)90073-3.

    Article  CAS  PubMed  Google Scholar 

  20. Osterballe O, Weeke B, Albrechtsen O: Influence of small atmospheric ions on the airways in patients with bronchial asthma. Allergy. 1979, 34: 187-194. 10.1111/j.1398-9995.1979.tb01566.x.

    Article  CAS  PubMed  Google Scholar 

  21. Albrechtsen O, Clausen V, Christensen FG, Jensen JG, Moller T: The influence of small atmospheric ions on human well-being and mental performance. Int J Biometeorol. 1978, 22: 249-262. 10.1007/BF01552806.

    Article  CAS  PubMed  Google Scholar 

  22. Dantzler BS, Martin BG, Nelson HS: The effect of positive and negative air ions on bronchial asthma. Ann Allergy. 1983, 51: 362-366.

    CAS  PubMed  Google Scholar 

  23. Finnegan MJ, Pickering CA, Gill FS, Ashton I, Froese D: Effect of negative ion generators in a sick building. Br Med J (Clin Res Ed). 1987, 294: 1195-1196. 10.1136/bmj.294.6581.1195.

    Article  CAS  Google Scholar 

  24. Reilly T, Stevenson IC: An investigation of the effects of negative air ions on responses to submaximal exercise at different times of day. J Hum Ergol (Tokyo). 1993, 22: 1-9.

    CAS  Google Scholar 

  25. Wagner CJ, Danziger RE, Nelson HS: Relation between positive small air ions, weather fronts and pulmonary function in patients with bronchial asthma. Ann Allergy. 1983, 51: 430-435.

    CAS  PubMed  Google Scholar 

  26. Yaglou CP: Are Air Ions a Neglected Biological Factor?. The Air We Breathe-A Study of Man and His Environment. Edited by: Farber SM, Wilson R. 1961, Charles C. Thomas: Springfield, Illinois

    Google Scholar 

  27. Lefcoe N: Ventilatory function after exposure to ionized air. Arch Environ Health. 1963, 7: 664-667. 10.1080/00039896.1963.10663597.

    Article  CAS  PubMed  Google Scholar 

  28. Motley HL, Yanda R: Environmental air pollution, emphysema and ionized air. Dis Chest. 1966, 50: 343-352. 10.1378/chest.50.4.343.

    Article  CAS  PubMed  Google Scholar 

  29. Rothstein H, Sutton A, Borenstein M: Publication Bias in Meta-Analysis: Prevention, Assessments, and Adjustments. 2005, West Sussex, England: Wiley

    Book  Google Scholar 

  30. Droppo JG: Ozone Field Studies Adjacent to a High-Voltage Direct-Current Test Line. In: Phillips RD, Gillis MF, Kaune WT, Mahlum DD (eds.). Biological Effects of Extremely Low-Frequency Electromagnetic Fields. 1979, Springfield, VA: National Technical Informatio Service, CONF-78-10-16, 501-529.

    Book  Google Scholar 

  31. Krupa SV, Pratt GC: UPA/CPA High Voltage Transmission LIne Potential Generation of Air Pollutants and their Impact on Vegetation. 1982, St. Paul, MN: Dept. of Plant Pathology, University of Minnesota

    Google Scholar 

  32. Varfalvy L, Dallaire RD, Maruvada PS, Rivest N: Measurement and statistical analysis of ozone from HVDC and HVAC transmission lines. Ieee T Power Ap Syst. 1985, 104: 2789-2997.

    Article  Google Scholar 

  33. FDA: Compliance Policy Guides Sec. 355.300 Ion Generating Devices. 1995, Silver Spring, MD: U.S. Food and Drug Administration, Available from: http://www.fda.gov/ICECI/ComplianceManuals/CompliancePolicyGuidanceManual/ucm073907.htm Last updated 22 December 2009 Available from: Last updated 22 December 2009

    Google Scholar 

  34. Kinne SM: A Public Health Approach to Evaluating the Significance of Air Ions. 1997, Houston, TX: University of Texas

    Google Scholar 

  35. Eisele FL, McDaniel EW: Mass spectrometric study of tropospheric ions in the southwestern and northeastern United States. J Geophys Res. 1986, 91: 5183-10.1029/JD091iD04p05183.

    Article  CAS  Google Scholar 

  36. Fews AP, Henshaw DL, Wilding RJ, Keitch PA: Corona ions from powerlines and increased exposure to pollutant aerosols. Int J Radiat Biol. 1999, 75: 1523-1531. 10.1080/095530099139124.

    Article  CAS  PubMed  Google Scholar 

  37. Fews AP, Wilding RJ, Keitch PA, Holden NK, Henshaw DL: Modification of atmospheric DC fields by space charge from high-voltage power lines. Atmospher Res. 2002, 63: 271-289. 10.1016/S0169-8095(02)00041-8.

    Article  Google Scholar 

  38. Melandri C, Tarrani G, Prodi V, Dezalcomo M, Formignani M, Lombardi CC: Deposition of charge particles in the human airways. J Aerosol Sci. 1983, 14: 657-669. 10.1016/0021-8502(83)90070-8.

    Article  Google Scholar 

  39. Scheuch G, Gebhart J, Roth C: Uptake of electrical charge in the human respiratory tract during exposure to air loaded with negative ions. J Aerosol Sci. 1990, 21: S439-S442.

    Article  Google Scholar 

  40. Observation of a group of subjects before, during, and after exposure to ionized air. Edited by: Yaglou CP. 1961, Springfield, IL: Charles C. Thomas Publisher

    Google Scholar 

  41. Board NRP(NRPB): Particle Deposition in the Vicinity of Power Lines and Possible Effects on Health. 2004, Didcot, Oxfordshire: National Radiological Protection Board

    Google Scholar 

  42. The Ministry of Health of the Russian Federation (MHRF): Sanitary and epidemiological norms on hygienic requirements to ionic air formula for industrial and public quarters. 2003, Moscow, Russia: Russian Ministry of Health Protection, 2.2.4.1294-03

    Google Scholar 

Download references

Acknowledgements

This work was partially funded by AltaLink LLC and Manitoba Hydro. However, the writing, data review, and interpretation were conducted independently by the authors and not reviewed by these funders prior to submission.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to William H Bailey.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

DDA conducted the analyses and contributed to the writing; VP, MEM, SS contributed to the writing and reviewed the manuscript; WHB contributed to the writing, review, submission and oversight of the manuscript. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Alexander, D.D., Bailey, W.H., Perez, V. et al. Air ions and respiratory function outcomes: a comprehensive review. J Negat Results BioMed 12, 14 (2013). https://doi.org/10.1186/1477-5751-12-14

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1477-5751-12-14